1.
BMC Health Serv Res ; 24(1): 407, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561774

RESUMO

BACKGROUND: As the COVID-19 pandemic swept across the globe at the beginning of 2020, healthcare systems were forced to rapidly adapt and expand to meet the sudden surge in demand for intensive care services. This study is the first systematic analysis of the strategies employed by German hospitals to recruit personnel and expand bed capacities during the first wave of the pandemic, and to evaluate the effectiveness of those recruitment measures. METHODS: 152 German hospitals with intensive care capacities were selected and invited to participate in an online-based retrospective survey. Factors like the geographic distribution, individual COVID burden and level of care were considered for inclusion in the sample. The data were analyzed descriptively. RESULTS: A total of 41 hospitals participated in the survey. The additional demand for intensive care beds was met primarily by activating intensive care beds that were previously considered as non-operational in existing intensive care units (81% of respondents) and by upgrading recovery rooms (73%). The physician staffing requirements were met at approximately 75%, while the nursing staffing requirements were only met by about 45%. Staffing needs were met through reallocations/transfers (85%), staff recruitment from parental leave or retirement (49%), increased hours worked by internal staff (49%), new staff hiring (44%) and increased use of temporary staff (32%). Staff reallocations/transfers to critical care within a hospital were rated as the most effective measure. In this context, specialized personnel mostly from anesthesiology departments were appointed to intensive care medicine. CONCLUSIONS: Despite multiple recruitment efforts, the pandemic has exacerbated the nursing staff shortage. The reallocation of existing staff within hospitals was a key element in covering the staffing needs. However, additional measures and efforts are required in order to ensure that critically ill patients can be cared for without compromise. The results of this study may have important implications for healthcare providers and policymakers, offering an evidence-based foundation for responding to future public health emergencies with agility, efficiency, and success.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Estudos Retrospectivos , Unidades de Terapia Intensiva , Cuidados Críticos , Recursos Humanos , Inquéritos e Questionários
2.
Biosensors (Basel) ; 12(12)2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36551114

RESUMO

OBJECTIVE: The main objective of this investigation is to provide data about the accuracy of total hemoglobin concentration measurements with respect to clinical settings, and to devices within the categories of point-of-care and reference systems. In particular, tolerance of hemoglobin concentrations below 9 g/dL that have become common in clinical practice today determines the need to demonstrate the limits of measurement accuracy in patient care. METHODS: Samples extracted from six units of heparinized human blood with total hemoglobin concentrations ranging from 3 to 18 g/dL were assigned to the test devices in a random order. The pool of test devices comprised blood gas analyzers, an automatic hematology analyzer, a laboratory reference method, and the point-of-care system HemoCue. To reduce the pre-analytic error, each sample was measured three times. Due to the characteristics of the tested devices and methods, we selected the mean values of the data from all these devices, measured at the corresponding total hemoglobin concentrations, as the reference. MAIN RESULTS: The measurement results of the test devices overlap within strict limits (R2 = 0.999). Only the detailed analysis provides information about minor but systematic deviations. In the group of clinically relevant devices, which are involved in patient blood management decisions, the relative differences were within the limit of +/- 5 % for values down to 3 g/dL. CONCLUSIONS: A clinically relevant change of +/- 0.5 g/dL of total hemoglobin concentration can be detected with all selected devices and methods. Compliance with more stringent definitions-these are the relative differences of 5 % in relation to the corresponding reference values and the clinically adapted thresholds in the format of a tolerance level analysis-was achieved by the clinical devices assessed here.


Assuntos
Hemoglobinas , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Hemoglobinas/análise , Gasometria
3.
Diagnostics (Basel) ; 11(12)2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-34943492

RESUMO

OBJECTIVE: Due to ongoing technical progress, the ultrasonic measurement of blood pressure (BP) as an alternative to oscillometric measurement (NIBP) or the continuous non-invasive arterial pressure method (CNAP) moves further into focus. The US method offers several advantages over NIBP and CNAP, such as deep tissue penetration and the utilization of different arterial locations. APPROACH: Ten healthy subjects (six female, aged 30.9 ± 4.6 years) volunteered in our investigation. In the ultrasonic BP measurement, we differentiated between the directly measured (pulsatile diastolic and systolic vessel diameter) and indirectly calculated variables at three different artery locations on both arms, with two different ultrasound devices in the transversal and longitudinal directions of the transducer. Simultaneously, NIBP monitoring served as reference BP, while CNAP monitored the steady state condition of the arm under investigation. The Moens-Korteweg algorithm (MKE) and the algorithm of the working group of San Diego (SanD) were selected for the indirectly calculated ultrasonic BP data. MAIN RESULTS: With US, we were able to measure the BP at each selected arterial position. Due to the investigation setup, we found small but significant interactions of the main effects. Bland and Altman analysis revealed that US-BP measurement was similar to NIBP, with superior accuracy when compared to the established CNAP method. In addition, US-BP measurement showed that the measurement accuracy of both arms can be regarded as identical. In a detailed comparison of the selected arterial vascular sections, systematic discrepancies between the right and left arm could be observed. CONCLUSION: In our pilot study, we measured BP effectively and accurately by US using two different devices. Our findings suggest that ultrasonic BP measurement is an adequate alternative for live and continuous hemodynamic monitoring.

SELEÇÃO DE REFERÊNCIAS